The stored thermal amount using prismaticsolar pond

Authors

  • Yousef Al khateeb
  • Somar Sudan

Abstract

According to the importance of economic solar ponds in domestic and industrial daily practical applications and its international widespread, this created the basis of an experimental study on a prismatic solar pond. It is internally painted in black with a surface measurement of (1m2) and a lower measurement of (0.42m2) and 1m deep. It constitutes four levels of gradual salinity separated by transparent glassy tablets /home glass/ of (6mm) thickness. On its lower level, a black solid mass is placed (black volcanic stones of equal dimensions; almost around 1cm). Upon studying the temperature and the stored thermal amounts of via subsidiary time every day from 9 am until 5 pm, the average rate of stored thermal amount each hour calculated according to the following equation:
(Q = m.Cp.ΔT) during six months (February until July 2016) was:
9962.445 KJ, 9516.28 KJ, 10783.471 KJ, 9765.836 KJ, 14010.393 KJ, 12164.320 KJ respectively.

 

Published

2018-09-30

How to Cite

1.
Al khateeb Y, Sudan S. The stored thermal amount using prismaticsolar pond. TUJ-BA [Internet]. 2018Sep.30 [cited 2024Apr.20];39(5). Available from: https://journal.tishreen.edu.sy/index.php/bassnc/article/view/4008